Monday, 26 December 2016

Frozen Pipes, what to do & how to prevent

Do you have a home or dwelling that has a chronic condition of pipes freezing every winter? In this blog I will touch on the following aspects of frozen pipes:

• How to minimize the chance of pipes freezing by preventative pipe installation techniques & some of the likely causes for frozen pipes and locations of the freeze points
• How to safely unfreeze a pipe
• What will happen if you don’t do anything and wait for the pipe to thaw naturally

How to minimize the chance of pipes freezing by preventative installation techniques:

If you are having an addition done on your existing home or building a new structure, you would hope that your contractor or builder would take precautions and adhere to guidelines that would prevent pipes from freezing but unfortunately the rules & regulations are not that stringent. We at True Restorations have seen some shoddy installation techniques all over Long Island in every type of structure.
Domestic water pipes & heating pipes are often times run in an unheated crawl as a necessity for the installation of the fixture. There usually are several options for running these pipes. The easier & faster option is to run the pipe below the beams so that time & energy is not wasted in drilling each beam and snaking the pipe through the beams. The slower option is obvious to do all that drilling. In either instance, the pipe should have some kind of pipe insulation over the pipe. Believe it or not, we often find pipes uninsulated and even the floor systems in crawl spaces uninsulated. Running the pipe in between the beams and having the beam cavities filled with fiberglass insulation as well as having the pipe insulated with a rigid insulation installed tightly will be one of the best preventative measure to protect against frozen pipes in a crawl space.


Another safe practice for pipe installation is to “never”, as in never ever, run a pipe in an exterior wall, a soffit or an overhang. I laugh at myself because as great as this sounds I have broken this cardinal sin of contracting as sometimes there is just no other way to run the pipe to its needed location. There are some precautions that you can take to lessen the chances of pipes freezing if this is an absolute must. One option would be to fur the wall out (make it thicker) son that more insulation can be installed between the pipe & the outside. A second option would be to add a heat tracer (a thermostatically controlled hard wired heating element) to the pipe.

Wind infiltration into, above or below heated spaces will be the likely location of a pipe freeze. The tiniest crack or space can let wind in and often times pressurize the air flow through this tighter space. A thermodynamic quality of gas (air) as it changes from higher pressures to lower pressures the gas experiences a cooling effect, this is how an A/C condenser produces cold air for your air conditioner.

The A/C condenser condenses the gas (pressurizes it), when the gas is unpressurized at the blower coil, the coil (metal) gets super cold and the fans blow air past the coil to extract the coldness. If you have ever let air pressurized air out of an O2 cylinder or scuba tank rapidly you would notice the freezing effect that it creates on the metal valves. This effect is part of what is causing the pipes of your dwelling to freeze at these wind infiltration points. Super cold conditions without wind can obviously cause pipes to freeze without wind conditions.


Additional pipe installation techniques that would help minimize pipe freezing’s that I won’t expand too much in order to keep this post reasonably short would be:

• The running of pipes through beams (above heated spaces below) & then projecting pipes out into cantilevers minimizing the amount of piping in soffit areas.
• The running of water mains up from below grade into a heated space with no fittings or valves in unheated areas. The valves or fittings become choke points for the water & provide greater metal surface areas to create a higher likelihood of freezing.
• Not using Pex fitting (especially elbow fittings) in unheated spaces. Pex piping is plastic piping & the fittings are metal. The metal acts as a heat sink and amplifies the freezing process at these water choke points. Pex, being plastic, is flexible and can be gradually bent and run in such a manner as to enable it to be installed without fitting to make a 90 degrees turn (elbows).
• The running of pipes to a vanity on an outside wall that come up from the floor into the bottom of the vanity rather than into the exterior wall would be another recommended practice.

For more info visit : http://truerestorations.com/